中华妇幼临床医学杂志(电子版) ›› 2006, Vol. 02 ›› Issue (05) : 264 -267. doi: 10.3877/cma.j.issn.1673-5250.2006.05.107

论著

新生儿急性呼吸衰竭机械通气下肺力学的动态监测及临床意义
王少华, 杨军, 杨华彬, 匡凤梧   
  1. 广东省深圳市福田区妇幼保健院新生儿科(深圳,518026)
    南方医科大学珠江医院新生儿科
    广州市儿童医院
    重庆医科大学儿童医院PICU
  • 出版日期:2006-09-21
  • 基金资助:
    广东省深圳市科技局2003年度立项(200304236); 深圳市福田区重点医学专科资助项目(2005)

To monitor the characteristics of respiratory mechanics in newborns with acute respiratory failure and to assess its clinical significance

Sha-ohua WANG, Jun YANG, Hua-bin YANG, Feng-wu KUANG   

  1. Women and Children Health Institute Futian, Shenzhen, 518026, Guangdong, China
  • Published:2006-09-21
引用本文:

王少华, 杨军, 杨华彬, 匡凤梧. 新生儿急性呼吸衰竭机械通气下肺力学的动态监测及临床意义[J/OL]. 中华妇幼临床医学杂志(电子版), 2006, 02(05): 264-267.

Sha-ohua WANG, Jun YANG, Hua-bin YANG, Feng-wu KUANG. To monitor the characteristics of respiratory mechanics in newborns with acute respiratory failure and to assess its clinical significance[J/OL]. Chinese Journal of Obstetrics & Gynecology and Pediatrics(Electronic Edition), 2006, 02(05): 264-267.

目的

探讨因急性呼吸衰竭而行机械通气新生儿呼吸系统力学特征,评价呼吸力学监测的临床意义。

方法

利用Bicore CP-100婴儿型呼吸力学监护仪对进入新生儿重症监护病房(neonatal intensive care unit, NICU)的36例急性呼吸衰竭患儿的呼吸力学动态监测,同时监测动脉血气。

结果

肺源性呼吸衰竭与呼吸泵性呼吸衰竭患儿呼吸力学参数两组上机时,差异有显著意义:Rrs(t = 2.47,P< 0.05),Crs(t = 2.78,P <0.01),WOBp(t=11.03,P<0.01),OI(t=18.26,P <0.01);OICrs有明显相关性(r=-0.93),有直线回归关系(Y = 34.09 — 42.61XP<0.01);死亡组与存活组上机时,呼吸力学参数差异有显著意义(P<0.05)。

结论

呼吸衰竭患儿机械通气下呼吸力学监测,可以反映新生儿肺部病情的动态变化,指导呼吸机治疗,判断预后,尤其对肺源性呼吸衰竭患儿有重要的实用价值,对区分肺源性呼吸衰竭与呼吸泵衰竭有着重要的参考意义。

Objectives

To explore the characteristics of respiratory mechanics in newborns with acute respiratory failure(ARF)during tracheal intubation.To assess the significance of respiratory mechanics monitoring.

Methods

The indices of respiratory mechanics were measured by Bicore CP-100 pulmonary monitor in 36 newborns admitted with the NICU due to acute respiratory failure during tracheal intubation.Their arterial blood gas were examined at the same time.

Results

There were significant differences between pulmonary failure and respiratory pump failure in Rrs(t = 2.47, P<0.05),Crs(t = 2.78, P<0.01),WOBp(t= 11.03 , P<0.01),OI(t=18.26, P<0.01).There was negative correlation and linear regression relation between Crs and OI(r = 0.93, Y = 34.09 — 42.61X,P<0.05).There were significant difference in indices of respiratory mechanics between non-survivors and survivors(P<0.05).

Conclusion

Respiratory mechanics monitoring during tracheal intubation in acute respiratory failure patients is valuable in evaluating the dynamic changes of lung's disease, directing the mechanical ventilation management and predicting outcome, especially in the pulmonary failure patients.It is of importance to distinguish pulmonary failure from respiratory pump failure.

1 王少华,杨军.匡凤梧等.新生儿急性呼吸衰竭呼吸机撤离时的呼吸力学研究.中华妇幼临床医学杂志.2005.1(2):96-98.
2 Petros AJ,Lamond CT, Dennett D.The Bicore pulmonary monitor.Anesthesia ,1993 ,48(7): 985-994.
3 Schaeffer D,Cemy F.Effect of chloral Hydrate on passive respiratory mechanics in infants.Physiologisy, 1985,28(1):330A.
4 William S,wilkia S.Nosoconial respiratory failure or iatrogenic ventilator dependency.Critic care med,1993,21(2): 171-173.
5 Kapasi M, Fujino Y, Kirmse M,et al.Effort and work of breathing in neonates during assisted patient-triggered ventilation.Pediatr Cric Care Med, 2001,2(1):9-16.
6 王少华,杨军,匡凤梧等.早产儿呼吸衰竭同步机械通气治疗的呼吸力学评价.中国危重病急救医学杂志,2004,16:670-672.
7 Smith J,Vanlierde S,Devlieher H,et al.Birth weight and early lung compliance as predictors of short-term outcome in premature infants with respiratory distress syndrome.S Afr Med J,1995,85(11):1157-1160.
8 Kessler V,Guttmann J,Newth CJ.Dynamic respiratory system mechanics in infants during pressure and volume controlled ventilation.Eur Respir J.2001,17(1):115-121.
[1] 费一鸣, 刘卓, 张丽娟. 组学分析在早产分子机制中的研究现状[J/OL]. 中华妇幼临床医学杂志(电子版), 2024, 20(05): 504-510.
[2] 韩肖燕, 杨桦. 中孕期孕妇血清胎盘生长因子水平低与胎儿不良预后的关系[J/OL]. 中华妇幼临床医学杂志(电子版), 2024, 20(04): 398-402.
[3] 徐婷婷, 詹泳池, 王晓东, 刘兴会. 电子胎心监测结果出现正弦波形的胎母输血综合征围生期结局分析[J/OL]. 中华妇幼临床医学杂志(电子版), 2024, 20(04): 382-389.
[4] 梅娟, 陶旭炜. 弥散性血管内凝血为首发表现先天性肝内门体静脉分流新生儿2例并文献复习[J/OL]. 中华妇幼临床医学杂志(电子版), 2024, 20(03): 322-330.
[5] 郑伟军, 郑超, 方一凡, 吴典明, 王翔, 陈飞, 刘明坤. 新生儿急性阑尾炎17例诊治分析并文献回顾[J/OL]. 中华普通外科学文献(电子版), 2024, 18(04): 291-293.
[6] 张璇, 高杨, 房雅君, 姚艳玲. 保护性机械通气在肺癌胸腔镜肺段切除术中的临床应用[J/OL]. 中华肺部疾病杂志(电子版), 2024, 17(04): 563-567.
[7] 刘婷, 杨少康, 陈亿霏, 刘悦, 潘纯. 气道闭合的监测在机械通气中的研究进展[J/OL]. 中华重症医学电子杂志, 2024, 10(04): 394-398.
[8] 潘清, 葛慧青. 基于机械通气波形大数据的人机不同步自动监测方法[J/OL]. 中华重症医学电子杂志, 2024, 10(04): 399-403.
[9] 苗明月, 周建新. 肺保护性镇静:应重视呼吸驱动和吸气努力的床旁评估[J/OL]. 中华重症医学电子杂志, 2024, 10(04): 325-328.
[10] 韦小霞, 陈管洁, 李雪珠, 李晓青, 钱淑媛. 机械通气患者抗菌药物雾化吸入的临床实施[J/OL]. 中华重症医学电子杂志, 2024, 10(04): 334-337.
[11] 刘春峰, 徐朝晖, 施红伟, 陈瑢, 马腾飞, 李鹏飞, 袁蓉, 陈建荣, 徐爱明. 机械通气患者肌肉减少症的诊断及其对预后的影响[J/OL]. 中华临床医师杂志(电子版), 2024, 18(09): 820-825.
[12] 李茂军, 唐彬秩, 吴青, 阳倩, 梁小明, 邹福兰, 黄蓉, 陈昌辉. 新生儿呼吸窘迫综合征的管理:多国指南/共识及RDS-NExT workshop 共识陈述简介和评价[J/OL]. 中华临床医师杂志(电子版), 2024, 18(07): 607-617.
[13] 李春光, 杨洋, 李斌, 华荣, 孙益峰, 李志刚. 不同外科修复模式治疗机械通气相关气管食管瘘的短期疗效评价[J/OL]. 中华胸部外科电子杂志, 2024, 11(03): 151-157.
[14] 刘晓鹏, 柳聪艳, 杨宁, 蔡琛, 李晓兵, 王红宇, 张思森. 三穴五针联合腹部提压法在机械通气患者肺康复中的疗效[J/OL]. 中华卫生应急电子杂志, 2024, 10(04): 193-198.
[15] 刘晴雯, 韩勇, 陈丽丹, 邓哲. 早期机械通气对成人院内心脏骤停病死率的影响:一项回顾性队列研究[J/OL]. 中华卫生应急电子杂志, 2024, 10(04): 203-206.
阅读次数
全文


摘要