新生儿急性呼吸衰竭呼吸机撤离时的呼吸力学研究
王少华, 杨军, 李志勇, 匡凤梧   
  1. 广东省深圳市福田妇幼保健院新生儿科(深圳,518045)
    第一军医大学珠江医院新生儿科
    重庆医科大学儿童医院ICU
  • 出版日期:2005-08-25
  • 基金资助:
    本课题为深圳市科委2003年立项资助项目(200304236)

The measurement of respiratory mechanics and its clinical significance in newborns weaning from mechanical ventilation

Shao-hua WANG, Jun YANG, Zhi-yong LI, Feng-wu KUAN   

  1. NICU Women and Children Health Institute Futian, Shenzhen, 518045, China
  • Published:2005-08-25
引用本文:

王少华, 杨军, 李志勇, 匡凤梧. 新生儿急性呼吸衰竭呼吸机撤离时的呼吸力学研究[J/OL]. 中华妇幼临床医学杂志(电子版), 2005, 01(02): 96-98.

Shao-hua WANG, Jun YANG, Zhi-yong LI, Feng-wu KUAN. The measurement of respiratory mechanics and its clinical significance in newborns weaning from mechanical ventilation[J/OL]. Chinese Journal of Obstetrics & Gynecology and Pediatrics(Electronic Edition), 2005, 01(02): 96-98.

目的

探讨新生儿机械通气撤机时呼吸力学指标的范围及临床意义。

方法

测定32例机械通气撤机时,新生儿在持续气道正压(CPAP )模式、脱机拔管前及拔管后20min等条件下的呼吸力学指标范围。根据拔管48h内是否重新插管,将以上病例分为撤机成功组与失败组。

结果

成功组的呼吸力学范围:平均气道阻力(Rawmean)为(93. 7 ± 14. 3)cmH2O/(L·S) (lcmH2O = 98. 07Pa)、呼吸系统顺应性(Crs)为(0. 65±0. 09)ml/(cmH2O · kg)、呼吸功(WOBp)为(1589± 133. 2)g · cm/(min · kg);失败组:Rawmean为(98. 6±15. 5)cmH2O/(L · S)、Crs为(0. 57±0. 08) ml/(cm H2O·kg)、WOBp为(1782±148. 6)g ·cm/(min · kg)。Crs与两组差异有显著意义(P<0. 05),脱机成功率为95.4%。

结论

呼吸力学的检测对新生儿呼吸机的撤离有指导作用,特别是对呼吸系统顺应性和呼吸功的检测,更具有实际意义。

Objectives

To explore the range of respiratory mechanics values on weaning ventilators in mechanical ventilated newborns and its clinical significance.

Methods

Thirty-two ventilated newborns were measured for indices of respiratory mechanics using a Bicore CP-100 pulmonary monitor under a continuous positive airways pressure of 3cmH2O, and in the periods of pre-extubation after ventilator weaning and 20 min post-extubation. Extubation success was defined as no reintubation within 48 hours of extubation.

Results

In the extubation success group, Rawmean (mean airway resistance) was (93. 7 ±14. 3)cmH2O/(L • S), Crs (respiratory system compliance) (0. 65 ± 0. 09) ml/(cmH2O • kg), WOBp(work of breathing, patient ) (1589 + 133. 2) g • cm/(min • kg); in the extubation failure group, Rawmean(98. 6+15. 5)cmH2O/(L • S), Crs(0. 57 ± 0. 08)ml/(cmH2O • kg), WOBp(1782 ± 148. 6) g • cm/(min •kg). There were significant differences between the two groups in Crs and WOBp. The rate of successful weaning was 95. 4%.

Conclusion

Bedside measurements of improved respiratory mechanics (WOBp, Crs)can be used to predict the outcome of mechanical ventilation withdrawal in neonates. Pulmonary function testing may help choose the optimal time for extubation in infants.

1 韩玉昆.呼吸机在儿科的临床应用.中国实用儿科杂志,1994,5:18-27.
2 Macdonale KD, David D,Wirttscharter M, et al. Continuous neonatal pulmonary mechanics with the Bircore CP-100 monitor. Neonatal intensive care,1992(11/12):55-61.
3 周晓光,肖欣,农绍汉主编.新生儿机械通气治疗学,第1版.北京:人民卫生出版社,2004,223-261.
4 Julian JA,Ephrain BY,Brya C,et al. Respiratory mechanics in infants :Physiologic evaluation in health and disease. Am Rev Respir dis, 1993,147:477-496.
5 王少华,匡凤梧,吴仕孝等.新生儿呼吸窘迫综合症呼吸力学的动态监测及离别意义.中国实用儿科杂志,2001,16(2):92-94.
6 Migdal M,Dreizzen E,Prand TP,et al. Compliance of the total respiratory system in healthy preterm and full-term newborns. Pediatr Pulmonol, 1987,3:214-222.
7 Balsam MJ, Jones JG, Watchko JF, et al. Measurement of pulmonary mechanics prior to the elective extubation of neonates. Pediatr Pulmonol, 1990,9:238-243.
8 Oca MJ, Becker MA, Dechert RE, et al. Relationship of neonatalendotracheal tube size and airway resistance. Respir Care,2002Sep,47(9):994-997.
9 Mehta S, Nelson DL, Klinger JR, et al. Prediction of post-extubation work of breathing. Crit Care Med, 2000 May, 28(5):1341-1346.
[1] 张烈, 严一核, 杜洁瑜. 分泌型白细胞蛋白酶抑制因子对无创呼吸机治疗重症肺炎患者的预测效能[J/OL]. 中华危重症医学杂志(电子版), 2024, 17(04): 301-306.
[2] 费一鸣, 刘卓, 张丽娟. 组学分析在早产分子机制中的研究现状[J/OL]. 中华妇幼临床医学杂志(电子版), 2024, 20(05): 504-510.
[3] 徐婷婷, 詹泳池, 王晓东, 刘兴会. 电子胎心监测结果出现正弦波形的胎母输血综合征围生期结局分析[J/OL]. 中华妇幼临床医学杂志(电子版), 2024, 20(04): 382-389.
[4] 韩肖燕, 杨桦. 中孕期孕妇血清胎盘生长因子水平低与胎儿不良预后的关系[J/OL]. 中华妇幼临床医学杂志(电子版), 2024, 20(04): 398-402.
[5] 梅娟, 陶旭炜. 弥散性血管内凝血为首发表现先天性肝内门体静脉分流新生儿2例并文献复习[J/OL]. 中华妇幼临床医学杂志(电子版), 2024, 20(03): 322-330.
[6] 张艳兰, 徐琳, 王彩英, 杨洪玲, 庞琳. 56例先天性梅毒新生儿的临床特征及预后[J/OL]. 中华实验和临床感染病杂志(电子版), 2024, 18(03): 163-169.
[7] 郑伟军, 郑超, 方一凡, 吴典明, 王翔, 陈飞, 刘明坤. 新生儿急性阑尾炎17例诊治分析并文献回顾[J/OL]. 中华普通外科学文献(电子版), 2024, 18(04): 291-293.
[8] 赵小欢, 尚志英, 段文超, 张晓燕, 孙东强. 无创通气治疗COPD 并发呼吸衰竭不同预后患者外周血MicroRNA及炎性因子水平分析[J/OL]. 中华肺部疾病杂志(电子版), 2024, 17(05): 777-780.
[9] 方晓玉, 王婷, 赵珊, 陈锋. HALP指数对AECOPD并发呼吸衰竭患者ICU结局的预测意义[J/OL]. 中华肺部疾病杂志(电子版), 2024, 17(04): 639-641.
[10] 刘娟娟, 李志华. 风险预警对无创呼吸机治疗肺心病并发呼吸衰竭的作用[J/OL]. 中华肺部疾病杂志(电子版), 2024, 17(04): 645-647.
[11] 杨坤, 赵景成, 吴永强. 无创呼吸机在慢性阻塞性肺疾病并发呼吸衰竭救治的临床分析[J/OL]. 中华肺部疾病杂志(电子版), 2024, 17(03): 481-483.
[12] 刘婷, 杨少康, 陈亿霏, 刘悦, 潘纯. 气道闭合的监测在机械通气中的研究进展[J/OL]. 中华重症医学电子杂志, 2024, 10(04): 394-398.
[13] 倪韫晖, 杨毅, 袁雪燕, 邱海波. 胸壁加压在急性呼吸窘迫综合征中的应用和临床进展[J/OL]. 中华重症医学电子杂志, 2024, 10(03): 243-247.
[14] 李茂军, 唐彬秩, 吴青, 阳倩, 梁小明, 邹福兰, 黄蓉, 陈昌辉. 新生儿呼吸窘迫综合征的管理:多国指南/共识及RDS-NExT workshop 共识陈述简介和评价[J/OL]. 中华临床医师杂志(电子版), 2024, 18(07): 607-617.
[15] 何秀, 敖的, 杨郑, 林小华. 改良呼吸支持策略对慢性阻塞性肺疾病急性加重合并Ⅱ型呼吸衰竭患者的疗效[J/OL]. 中华卫生应急电子杂志, 2024, 10(03): 140-144.
阅读次数
全文


摘要