中华妇幼临床医学杂志(电子版) ›› 2005, Vol. 01 ›› Issue (02) : 96 -98. doi: 10.3877/cma.j.issn.1673-5250.2005.02.108

论著

新生儿急性呼吸衰竭呼吸机撤离时的呼吸力学研究
王少华, 杨军, 李志勇, 匡凤梧   
  1. 广东省深圳市福田妇幼保健院新生儿科(深圳,518045)
    第一军医大学珠江医院新生儿科
    重庆医科大学儿童医院ICU
  • 出版日期:2005-08-25
  • 基金资助:
    本课题为深圳市科委2003年立项资助项目(200304236)

The measurement of respiratory mechanics and its clinical significance in newborns weaning from mechanical ventilation

Shao-hua WANG, Jun YANG, Zhi-yong LI, Feng-wu KUAN   

  1. NICU Women and Children Health Institute Futian, Shenzhen, 518045, China
  • Published:2005-08-25
引用本文:

王少华, 杨军, 李志勇, 匡凤梧. 新生儿急性呼吸衰竭呼吸机撤离时的呼吸力学研究[J]. 中华妇幼临床医学杂志(电子版), 2005, 01(02): 96-98.

Shao-hua WANG, Jun YANG, Zhi-yong LI, Feng-wu KUAN. The measurement of respiratory mechanics and its clinical significance in newborns weaning from mechanical ventilation[J]. Chinese Journal of Obstetrics & Gynecology and Pediatrics(Electronic Edition), 2005, 01(02): 96-98.

目的

探讨新生儿机械通气撤机时呼吸力学指标的范围及临床意义。

方法

测定32例机械通气撤机时,新生儿在持续气道正压(CPAP )模式、脱机拔管前及拔管后20min等条件下的呼吸力学指标范围。根据拔管48h内是否重新插管,将以上病例分为撤机成功组与失败组。

结果

成功组的呼吸力学范围:平均气道阻力(Rawmean)为(93. 7 ± 14. 3)cmH2O/(L·S) (lcmH2O = 98. 07Pa)、呼吸系统顺应性(Crs)为(0. 65±0. 09)ml/(cmH2O · kg)、呼吸功(WOBp)为(1589± 133. 2)g · cm/(min · kg);失败组:Rawmean为(98. 6±15. 5)cmH2O/(L · S)、Crs为(0. 57±0. 08) ml/(cm H2O·kg)、WOBp为(1782±148. 6)g ·cm/(min · kg)。Crs与两组差异有显著意义(P<0. 05),脱机成功率为95.4%。

结论

呼吸力学的检测对新生儿呼吸机的撤离有指导作用,特别是对呼吸系统顺应性和呼吸功的检测,更具有实际意义。

Objectives

To explore the range of respiratory mechanics values on weaning ventilators in mechanical ventilated newborns and its clinical significance.

Methods

Thirty-two ventilated newborns were measured for indices of respiratory mechanics using a Bicore CP-100 pulmonary monitor under a continuous positive airways pressure of 3cmH2O, and in the periods of pre-extubation after ventilator weaning and 20 min post-extubation. Extubation success was defined as no reintubation within 48 hours of extubation.

Results

In the extubation success group, Rawmean (mean airway resistance) was (93. 7 ±14. 3)cmH2O/(L • S), Crs (respiratory system compliance) (0. 65 ± 0. 09) ml/(cmH2O • kg), WOBp(work of breathing, patient ) (1589 + 133. 2) g • cm/(min • kg); in the extubation failure group, Rawmean(98. 6+15. 5)cmH2O/(L • S), Crs(0. 57 ± 0. 08)ml/(cmH2O • kg), WOBp(1782 ± 148. 6) g • cm/(min •kg). There were significant differences between the two groups in Crs and WOBp. The rate of successful weaning was 95. 4%.

Conclusion

Bedside measurements of improved respiratory mechanics (WOBp, Crs)can be used to predict the outcome of mechanical ventilation withdrawal in neonates. Pulmonary function testing may help choose the optimal time for extubation in infants.

1 韩玉昆.呼吸机在儿科的临床应用.中国实用儿科杂志,1994,5:18-27.
2 Macdonale KD, David D,Wirttscharter M, et al. Continuous neonatal pulmonary mechanics with the Bircore CP-100 monitor. Neonatal intensive care,1992(11/12):55-61.
3 周晓光,肖欣,农绍汉主编.新生儿机械通气治疗学,第1版.北京:人民卫生出版社,2004,223-261.
4 Julian JA,Ephrain BY,Brya C,et al. Respiratory mechanics in infants :Physiologic evaluation in health and disease. Am Rev Respir dis, 1993,147:477-496.
5 王少华,匡凤梧,吴仕孝等.新生儿呼吸窘迫综合症呼吸力学的动态监测及离别意义.中国实用儿科杂志,2001,16(2):92-94.
6 Migdal M,Dreizzen E,Prand TP,et al. Compliance of the total respiratory system in healthy preterm and full-term newborns. Pediatr Pulmonol, 1987,3:214-222.
7 Balsam MJ, Jones JG, Watchko JF, et al. Measurement of pulmonary mechanics prior to the elective extubation of neonates. Pediatr Pulmonol, 1990,9:238-243.
8 Oca MJ, Becker MA, Dechert RE, et al. Relationship of neonatalendotracheal tube size and airway resistance. Respir Care,2002Sep,47(9):994-997.
9 Mehta S, Nelson DL, Klinger JR, et al. Prediction of post-extubation work of breathing. Crit Care Med, 2000 May, 28(5):1341-1346.
[1] 李博, 孔德璇, 彭芳华, 吴文瑛. 超声在胎儿肺静脉异位引流诊断中的应用价值[J]. 中华医学超声杂志(电子版), 2023, 20(04): 437-441.
[2] 杨皓媛, 龚杰, 邹青伟, 阮航. 哮喘孕妇的母婴不良妊娠结局研究现状[J]. 中华妇幼临床医学杂志(电子版), 2023, 19(05): 522-529.
[3] 李文琳, 羊玲, 邢凯慧, 陈彩华, 钟丽花, 张娅琴, 张薇. 脐动脉血血气分析联合振幅整合脑电图对新生儿窒息脑损伤的早期诊断价值分析[J]. 中华妇幼临床医学杂志(电子版), 2023, 19(05): 550-558.
[4] 董晓燕, 赵琪, 唐军, 张莉, 杨晓燕, 李姣. 奥密克戎变异株感染所致新型冠状病毒感染疾病新生儿的临床特征分析[J]. 中华妇幼临床医学杂志(电子版), 2023, 19(05): 595-603.
[5] 魏徐, 张鸽, 伍金林. 新生儿脓毒症相关性凝血病的监测和治疗[J]. 中华妇幼临床医学杂志(电子版), 2023, 19(04): 379-386.
[6] 胡诤贇, 史建伟, 申建伟, 王冰, 蒋春苗, 刘冲. 基于机器学习鉴定早产儿支气管肺发育不良的关键基因[J]. 中华妇幼临床医学杂志(电子版), 2023, 19(04): 446-454.
[7] 杨莹, 刘艳, 王央丹. 新生儿结节性硬化症相关性癫痫1例并文献复习[J]. 中华妇幼临床医学杂志(电子版), 2023, 19(04): 464-472.
[8] 王泽想, 高艳, 赵岩, 杨秀清, 李梦华, 王振华, 许晓英, 杨琼, 于占营, 王爱霞, 贺刚, 刘景院. 三例人类肺型鼠疫患者临床特征分析[J]. 中华实验和临床感染病杂志(电子版), 2023, 17(05): 341-347.
[9] 张海金, 王增国, 蔡慧君, 赵炳彤. 2020至2022年西安市儿童医院新生儿细菌感染分布及耐药监测分析[J]. 中华实验和临床感染病杂志(电子版), 2023, 17(04): 222-229.
[10] 汪俊谷, 潘华琴, 杨雨田. HFNC治疗急性低氧性呼吸衰竭插管预后及影响因素分析[J]. 中华肺部疾病杂志(电子版), 2023, 16(04): 523-525.
[11] 钱晓英, 吴新, 徐婷婷. 颅脑损伤并发呼吸衰竭患者早期机械通气的效果分析[J]. 中华肺部疾病杂志(电子版), 2023, 16(04): 526-528.
[12] 芦丹, 杨硕, 刘旭. VEGF、HMGB1、hs-CRP/Alb在AECOPD伴呼吸衰竭中的变化及预后分析[J]. 中华肺部疾病杂志(电子版), 2023, 16(04): 532-534.
[13] 代芬, 卞士柱. 无创机械通气联合肺康复在肺动脉高压呼吸衰竭治疗中的临床应用[J]. 中华肺部疾病杂志(电子版), 2023, 16(04): 560-562.
[14] 张瑜, 李冉, 彭书芳, 刘玲. 胃癌术后发生腹腔间隔室综合征并发呼吸衰竭患者救治成功一例[J]. 中华肺部疾病杂志(电子版), 2023, 16(03): 453-454.
[15] 李变, 王莉娜, 桑田, 李珊, 杜雪燕, 李春华, 张兴云, 管巧, 王颖, 冯琪, 蒙景雯. 亚低温技术治疗缺氧缺血性脑病新生儿的临床分析[J]. 中华临床医师杂志(电子版), 2023, 17(06): 639-643.
阅读次数
全文


摘要