切换至 "中华医学电子期刊资源库"

中华妇幼临床医学杂志(电子版) ›› 2013, Vol. 09 ›› Issue (05) : 660 -662. doi: 10.3877/cma.j.issn.1673-5250.2013.05.021

所属专题: 文献

短篇论著

婴幼儿及学龄前儿童经外周静脉穿刺置入中心静脉导管置管的体表测量方法探讨
雷素华1, 赵秀芳1,*(), 马晶晶1, 张静1, 章小燕1   
  1. 1. 610041 成都,四川大学华西第二医院小儿血液科
  • 收稿日期:2013-07-01 修回日期:2011-09-12 出版日期:2013-10-01
  • 通信作者: 赵秀芳
  • 基金资助:
    四川省卫生厅科研项目(120273)
  • Received:2013-07-01 Revised:2011-09-12 Published:2013-10-01
引用本文:

雷素华, 赵秀芳, 马晶晶, 张静, 章小燕. 婴幼儿及学龄前儿童经外周静脉穿刺置入中心静脉导管置管的体表测量方法探讨[J]. 中华妇幼临床医学杂志(电子版), 2013, 09(05): 660-662.

表1 两组患儿基本临床资料(±s)
Table 1 General clinical data in two groups(±s)
表2 两组患儿置管上肢及穿刺静脉[n(%)]
Table 2 Puncture limbs and vein in two groups[n(%)]
表3 两组患儿所置入PICC的相关数据(cm,±s)
Table 3 Related data of PICC between two groups(cm,±s)
表4 两组患儿体外测量PICC预置长度与最适长度之间差异比较(cm,±s)
Table 4 Comparison of length by external measurement and suitable length of PICC (cm,±s)
表5 影响PICC最适长度的相关因素
Table 5 The related factors of suitable length of PICC
1
Infusion Nurses Society. Infusion nursing standards of practice[J].J Infus Nurs,2006,29(1):1-92.
2
Li J, Li J, Li SL,et al.Relationship between the length by external measurement and the standard length of PICC[J]. J Nurs Sci,2010,25(15):65-66.
3
He HX, Liu XH, Xu B,et al. Research and application in the length of PICC[J].J Pract Nurs,2003,19(3):44-45.
4
Liu XH, Xue B, Yang ZY,et al. Study of different measurements in NICU[J].J Qilu Nurs,2010,16(7):26-27.
5
Wang XY, Xu C, Chen XR,et al. One regular fonts to make sure the length of PICC[J].Chin J Nurs,2004,39(5):360.
6
Liu CL, Yan MQ, Lu ZQ,et al. Research progress of pipe end positioning technology improvement of PICC[J].Shanghai Nurs, 2011, 11(2):75-78.
7
Wang JR. Infusion nursing practice guidelines and rules for implementation[M].Beijing:People's Military Medical Press,2009,10,21.
8
Knue M, Doetlman D, Jacobs BR.Peripherally inserted central catheters in children: A survey of practice patterns[J].J Infus Nurs,2006,29(1):28-33.
9
Cadman A, Lawrance JA. To clot or not to clot? That is the question in central venous catheters[J]. Clin Radiol,2004,59(4):349-355.
10
Kearns PJ, Coleman S, Wehner JH. Complications of long arm catheters: A randomed trial of central vs peripheral tip location[J].J Parenter Enteral Nutr,1996,20:20-24.
11
Lin ZZ, Zhang GY, Jin L,et al. Effect of neonatal PICC terminal position of catheter indwelling catheter[J].Chin J Pract Nurs,2006,22(2):33-34.
12
Miehelle E, Thanh H.Optimizing the patient positioning for PICC line tip determination[J].Emerg Radiol,2004,10(12):186-189.
13
Chen XR, Wang XY, Li L,et al.The analysis of the causes of 14 PICC with ectopic[J].Nurs J Chin PLA,2005,22(7):68-69.
14
Markovich MB.The expanding role of the infusion nurse in radiographic interpretation for peripherally inserted central catheter tip placement[J].J Infus Nurs,2008,31(2):96-103.
15
Orme RM, McSwiney MM, Chamberlain-Webber RF. Fatal cardiac tamponade as a result of a peripherally inserted central venous catheter:A case report and review of the literature[J].Br J Anaesth,2007,99(3):384-388.
16
Hsu JH, Wang CK, Chu KS,et al. Comparison of radiographic landmarks and echocardiographic SVC/RA junction in the positioning of long-term central venous catheters[J]. Acta Anaesthesiol Seand,2006,50:731-735.
17
Du P, He PY, He MQ, et al.Comparison of two different external measurement methods of PICC[J]. J Nurs Sc,2008,23(2):41-43.
18
Zhou HQ, Yang B. Analysis of PICC by the X-ray film[J]. J Pract Med Tech,2005,12(8):2009-2010.
19
Wang XH, Wang LJ. Catheter and nursing care of three valve peripheral central vein[J].J Pract Nurs,2003,9(3):41-42.
20
Liao YP. Children's anatomy[M].Shanghai: Shanghai Science and Technology Press,1987, 298-318.
21
Lei GH, Wang XH, Wang XJ.The calculation method of inserted length of peripherally inserted central catheter[J].Chin J Nurs,2010,45(4):345-346.
22
Liu Q.Study on methods of measuring the length of PICC to beinserte[D]. Tianjing:Tianjing Med Univ,2011,51.